Metrics
Last modified by bengt on 2025/03/20 14:08
Climate-based daylight performance metrics
The metrics for climate-based daylight can be defined by clicking "Metrics", given that "Climate-based daylight" simulation is selected. This simulation type is only available in the Beta version.

In Beta version only
The following metrics exist per default:
| Metric name | Description |
| AVG | The average value over time of the measurement field during the simulation. |
| MAX | The maximum value over time of the measurement field during the simulation. |
| DA | The percentage of measured area that receives at least L lux for at least 50%. The limits L can be adjusted using FIELD-LIMITS. (DA = Daylight Autonomy) |
| CDA | The percentage of measured area that receives at least L lux for at least 50% (Partial credit possible). The limits L can be adjusted using FIELD-LIMITS. (CDA = Continuous Daylight Autonomy) |
| SDA | The percentage of measured area that receives at least L lux for at least 50% of the occupied time. The limits L can be adjusted using FIELD-LIMITS. Calculated according to EN 17037. (SDA = Spatial Daylight Autonomy). |
| LEED_SDA | The percentage of measured area that receives at least L lux for at least 50% of the occupied time. The limits L can be adjusted using FIELD-LIMITS. Calculated according to LM-83. (SDA = Spatial Daylight Autonomy). |
| ASE | The percentage of measured area that receives at least L lux of direct sunlight for at least 250 occupied hours per year. The limits L can be adjusted using FIELD-LIMITS. (ASE = Annual Sunlight Exposure). |
| UDI | (UDI = Useful Daylight Illuminance) |
| INSOLATION | Insolation, total irradiance on the measurement plane in kWh per square meter |
| HOURSABOVE10 | The number of hours that the measurement exceeds the limit(s) given by FIELD-LIMITS. |
| BREEAM_AVG | The number of hours the illuminance exceeds the limit(s) given by FIELD-LIMITS (average over plane). |
| BREEAM_MIN | The number of hours the illuminance exceeds the limit(s) given by FIELD-LIMITS (pointwise). The minimum is computed using aggregate. |
| H_NUTZ_A_REL | Analysis according to German standard DIN 5034-3 (H_Nutz,A,rel). |
Each metric is defined by the following parameters, which can be changed:
| Parameter name | Type/Range | Description |
| ENABLED | True, False | Decide if the metric should be computed |
| DISPLAYNAME | Any string | The base name that will be used in reports |
| FIELD-LIMITS | List of positive values | List of lower and upper limits, for e.g., sDA. Must always be a list that starts and ends with parantheses. |
| INPERCENT | True, False | Decide if the result in report should be given as a percentage |
| TIME-AGGREGATION | avg, max, boolean, fuzzy, integral, hoursAbove | How the metric should be according time-aggregation-wise |
| NORMCONST | none (no normalization will be made) count (the number of included time steps in the calculation will be used for normalization) constantOccupancy (the constant occupancy of 4380 hours/year will be used for normalization) totalHoursOfOccupancy (the total hour of occupancy in the occupancy data is calculated and used for normalization) | How to normalize the result |
| APPLIESTOFIELDS | all (the metric will apply to all 7 possible input fields: ill_all_drawn, ill_none_drawn, ill_controlled, dir_all_drawn, dir_none_drawn, dir_all_drawn, dir_controlled, irr 'illuminance', the metric will apply to the input fields: ill_all_drawn, ill_none_drawn, ill_controlled) irradiance (the metric will apply to the input field: irr) direct illuminance (the metric will apply to the input fields: dir_all_drawn, dir_none_drawn, dir_all_drawn, dir_controlled) | Which fields of the measurement plane that the metric should apply to |
| TIMEFLAGS | whenOcc (True/False, it is necessary for the zone to be occupied for the time step to count) whenDay (True/False, it is necessary for the direct irradiance to be over 120 W/m^2 for the time step to count (daytime)) whenBright (True/False, it is necessary for the diffuse irradiance to be larger than a computed limit for the time step to count) | How to time filter the metric, several can be be active. |
| RESULTTYPENAME | noskip (the metric will be joined to the input field with an underscore, e.g., max_dir_none_drawn) skip (the metric will be joined with the suffix (all_drawn/none_drawn/controlled) with an underscore, e.g., Leed_sDA100_controlled) override (the metric will be used directly, e.g., Insolation) | Which rule to use when naming the results. |
| ONLYFORWHOLEYEAR | True/False | defines if the metric is to be done only for whole-year simulations |
| UNIT | base (the unit of the input field will be used) base+ABC (the unit of the input field will be used, with (ABC) appended) any text ("any text" will be used as the unit) | Defines how the unit of the metric-input field combination is generated |
| GRANULARITY | Pointwise (treat the plane measuring point by measuring point, Plane (average the value of all points in the plane) | The granularity of the plane |
| AGGREGATE-OPERATOR | % <, % >, <, > | Comparison to be done for aggregation over the plane |
| AGGREGATE-LIMIT | List of positive value(s) | The limit(s) that should be used for aggregation over the plane. Must always be a list that starts and ends with parantheses. |
| REPORT-TABLE | True/False | If the metric should be included in the report table (Results) |
| REPORT-IMAGE | True/False | If the metric should be included in the report image |