Choice of output

Last modified by Claudia Bless on 2026/08/26 10:21

1684224147437-175.png

Output from a simulation is presented as diagrams and reports. There are several different diagrams to choose from. The selection is made from the Choice of output dialog that is accessed by clicking on the Requested output button in the building form or if Choose output is selected in the Tools menu. The following diagram and reports exist (those marked with # are pre-selected but can be deleted):

Diagrams

Building level:

AHU temperatures (#) Air temperatures in central AHU

AHU airflows Air flows through central AHU

Plant temperatures Plant temperatures: Boiler & chiller, in & out

Total heating and cooling (#) Heat and cooling supplied by plant and ideal room units

Wind speed Wind speed and direction

Plant details: Detailed measures from an ESBO plant model

Occupancy Current total number of occupants in building

Solar radiation against facade Sum of direct and diffuse (sky + ground) solar radiance on façades with a window

Electrical system Electrical power from the grid, locally produced and used power

Zone level:

Main temperatures (#) Air and operative temperatures

Heat balance Detailed heat balance for zone

Air temperatures at floor and ceiling Air temperatures at floor and ceiling in case of displacement ventilation.

Fanger’s comfort indices Fanger's comfort indices, PPD, PMV

Indoor Air Quality Indoor air quality measures: Ac/h, CO2 level, humidity

Daylighting Daylight level at desktop (1st person)

Directed operative temperatures

Air flow in zone Air flows in zone, in/out through internal/external walls or mechanical ventilation

Airborne heat flow into zone Airborne net heat flows into zone, through internal walls, envelope and mechanical ventilation

Surface temperatures Temperatures of zone surfaces

Surface heat fluxes Total heat fluxes of zone surfaces

Convective heat fluxes Convective heat fluxes from sources and surfaces to the zone air

Ventilation air flows Ventilation air flows through terminals, windows, openings and leaks

Shading control Control signal of window shading

Occupancy Current number of occupants in zone

Solar radiation through window Direct, diffuse and total (including indirect) solar energy transmission through each window glazing. 

Reports

Building level:

Delivered energy (#) Totals of energy, purchased or locally generated, including cost, CO2 and primary energy

Time series of underlying measurements can be logged by logging sources

Trading report (#) Purchased and exported energy between different traders and costs

Time series of underlying measurements can be logged by logging sources 

Systems energy Overview of energy transferred by HVAC systems (preselected - cannot be unselected)

Lost work Account of work hours lost due to over or under heating

AHU energy (#) Energy transferred by individual Air Handling Units

Time series of underlying measurements can be logged by logging sources

Input data report (#) A report with gathered input data from the model (e.g. U-values and thermal bridges)

Electrical energy report Data for the electricity system and monthly values of the electricity energy balance 

Reference floor area for reports: If another floor area than the one calculated from the model should be used, it should be given here

Zone level:

Energy (#) Zone sensible energy balance

Time series of underlying measurements can be logged by logging sources

Thermal comfort According to the standard EN-16798-1