Choice of output

Output from a simulation is presented as diagrams and reports. There are several different diagrams to choose from. The selection is made from the Choice of output dialog that is accessed by clicking on the Requested output button in the building form or if Choose output is selected in the Tools menu. The following diagram and reports exist (those marked with # are pre-selected but can be deleted):
Diagrams
Building level:
AHU temperatures (#) Air temperatures in central AHU
AHU airflows Air flows through central AHU
Plant temperatures Plant temperatures: Boiler & chiller, in & out
Total heating and cooling (#) Heat and cooling supplied by plant and ideal room units
Wind speed Wind speed and direction
Plant details: Detailed measures from an ESBO plant model
Occupancy Current total number of occupants in building
Solar radiation against facade Sum of direct and diffuse (sky + ground) solar radiance on façades with a window
Electrical system Electrical power from the grid, locally produced and used power
Zone level:
Main temperatures (#) Air and operative temperatures
Heat balance Detailed heat balance for zone
Air temperatures at floor and ceiling Air temperatures at floor and ceiling in case of displacement ventilation.
Fanger’s comfort indices Fanger's comfort indices, PPD, PMV
Indoor Air Quality Indoor air quality measures: Ac/h, CO2 level, humidity
Daylighting Daylight level at desktop (1st person)
Directed operative temperatures
Air flow in zone Air flows in zone, in/out through internal/external walls or mechanical ventilation
Airborne heat flow into zone Airborne net heat flows into zone, through internal walls, envelope and mechanical ventilation
Surface temperatures Temperatures of zone surfaces
Surface heat fluxes Total heat fluxes of zone surfaces
Convective heat fluxes Convective heat fluxes from sources and surfaces to the zone air
Ventilation air flows Ventilation air flows through terminals, windows, openings and leaks
Shading control Control signal of window shading
Occupancy Current number of occupants in zone
Solar radiation through window Direct, diffuse and total (including indirect) solar energy transmission through each window glazing.
Reports
Building level:
Delivered energy (#) Totals of energy, purchased or locally generated, including cost, CO2 and primary energy
Time series of underlying measurements can be logged by logging sources
Trading report (#) Purchased and exported energy between different traders and costs
Time series of underlying measurements can be logged by logging sources
Systems energy Overview of energy transferred by HVAC systems (preselected - cannot be unselected)
Lost work Account of work hours lost due to over or under heating
AHU energy (#) Energy transferred by individual Air Handling Units
Time series of underlying measurements can be logged by logging sources
Input data report (#) A report with gathered input data from the model (e.g. U-values and thermal bridges)
Electrical energy report Data for the electricity system and monthly values of the electricity energy balance
Reference floor area for reports: If another floor area than the one calculated from the model should be used, it should be given here
Zone level:
Energy (#) Zone sensible energy balance
Time series of underlying measurements can be logged by logging sources
Thermal comfort According to the standard EN-16798-1