Monitor Variables dialog box
Monitor Variables dialog box
The Monitor Variables dialog box is used to edit the list of variables that are shown during the simulation in the Monitor window.
To display this dialog, select a variable and choose Monitor item from its shortcut menu. The dialog is also displayed when a variable is added to the monitor list.

Monitor Variable dialog box
Max time per screen
Specify the time period (in simulation time units) corresponding to the width of the monitor window. This field is not used in applications with calendar-based time scale.
Monitor variables
Displays the list of monitored variables. The buttons to the right of the list allows reordering and deleting variables from the list.
In the current version of IDA Modeler, only the top 3 variables are displayed in Monitor window.
Range
Supply two values of the selected variable. These values should correspond to the horizontal lines on the Monitor window.
Legend
Specify the explanation text for the selected variable to be displayed in the Monitor window.