Table group: Envelope

By right-clicking an object, it can be interacted with by common copy/paste-commands as well as scripts.

The table Windows shows all windows and skylights in the building, both inserted in zones and in faces (on a building body).
Name | The window name |
|---|---|
Type | Window, Window (detailed) or SkyLight |
Group | The zone group name. Shown as "n.a." (not applicable) for windows inserted into faces and having no adjacent zones |
Zone | The zone in which the window is inserted. |
Face | The face towards which the window faces or, for internal windows, the adjacent zone. |
| External or Internal | The face type of the window. |
Sill height from ground | Distance from ground level to lowest point of the window. |
Sill height from floor | Distance from zone floor level to lowest point of the window. |
Azimuth | 0 for windows faced to North, 90 to East, etc. Empty for horizontal windows |
Slope | From 0 for floor to 180 for ceiling |
Area | The window area including the frame. For skylights – the base area. |
Glazing | The glass construction |
g (SHGC) | The Solar heat gain coefficient of the glazing |
T | The solar transmittance of the glazing |
Glazing U | The U-value of the glazing |
Frame fract | The fraction of the frame. Empty for skylights. |
Frame U | The U-value of the frame. Empty for skylights. |
Win total U | The overall U-value of the window. Empty for skylights. |
Int Shading | The type of the integrated shading. For detailed windows available only if the window construction contains a shading layer |
Control | Selection of control strategy for integrated shading device. |
Schedule | Schedule for integrated shading, 1=completely drawn, 0=completely open |
Ext shading | Choice of external window shading |
Opening control | Selection of control strategy for window opening |
Opening schedule | Schedule for degree of window opening, 0 = fully closed, 1 = fully open |
The table Surfaces shows all walls, the floor and the ceiling of the zones in the building.
Name | The surface name |
|---|---|
Group | The zone group name |
Type | Roof/wall/floor, external or internal. In case of mixed external/internal the percent of mixture is shown |
Area | The area of the inner surface of the wall, excluding windows, openings, and doors |
Connected to | The list of the zones and faces on the other side of the wall |
Azimuth | 0 for walls faces to North, 90 to East, etc. Empty for horizontal surfaces |
Slope | From 0 for floor to 180 for ceiling |
Construction | Wall construction. Shown as "<mixed>" and non-editable for mixed internal/external walls. Constructions of any wall parts are not shown here. |
U-value | The U-value of the construction at standard conditions . Shown as "<mixed>" for mixed internal/external walls. |
Thickness | The total thickness of the construction. For mixed constructions, both values are shown: external / internal |
Layer material | The material of the 1-st layer (the layers are ordered as defined in the wall construction). Empty for mixed constructions. |
Layer thickness | The thickness of the 1-st layer. Empty for mixed constructions. |
Layer material etc. | The material of the 2-nd layer etc. |
The table Wall parts
An editable list of all wall parts in the building with similar columns to the "surfaces" table as described above.
The table Openings shows all oin the building, both inserted in zones and in faces (on a building body).
Name | The opening name |
|---|---|
Type | Type of opening |
Group | The opening group name. Shown as "n.a." (not applicable) for openings inserted into faces and having no adjacent zones |
Zone | The zone in which the opening is inserted. |
Face | The face towards which the opening faces or, for internal leaks, the adjacent zone. |
| External or internal | Type of the opening |
Azimuth | 0 for openings faced to North, 90 to East, etc. Empty for horizontal openings |
Slope | From 0 for floor to 180 for ceiling |
Area | The opening area. |
Construction | The opening construction |
| U-value | The heat transfer coefficient (u-value, W/(m2*K)) |
Opening schedule | Schedule for degree of window opening, 0 = fully closed, 1 = fully open |
Equivalent leak area | Leak area for closed internal doors |
Inner surface | The name of the choosen inner surface with given properties |
Outer surface | The name of the choosen outer surface with given properties |
Annotations | Annotations of the opening |
The table Leaks shows all leaks of the building inserted in zones.
Name | Name of the leak |
|---|---|
Group | The leak group name. |
Zone | The zone in which the leak is inserted. |
Face | The face towards which the leak is inserted or, for internal leaks, the adjacent zone. |
Azimuth | 0 for leaks faced to North, 90 to East, etc. Empty for horizontal openings |
Slope | From 0 for floor to 180 for ceiling |
Inpar | 0 if Leak area (ELA) is choosen and 1 if Powerlaw coef (CT) is choosen |
ELA | Equivalent leak area, which is the opening area multiplied by the discharge coeffiecient, Cd, at 4 Pa pressure difference, dP |
CT | Powerlaw coefficient (kg/(s*Pa^n) |
N | Powerlaw exponent (massflow = CT * dP^N) |
| Annotations | Annotaions of the leak |
The table Wall constructions shows all wall constructions available in the building. See the description of the columns of the Surfaces table
The table Materials shows all materials available in the building.
The table Facades and roof shows all roof parts and wall faces in the building model, along with their pressure coefficients. These coefficients are also available int the "Pressure coefficients" form in Global data.