Switzerland 4.8.0.2 changelog
Last modified by WikiBot on 2026/07/24 10:24
Switzerland 4.8.0.2 changelog
New in localization Switzerland 4.802 (relative to 4.801)
- In the weather data database, the reference height for wind measurements was adjusted according to SIA 2028:2010
- SIA 2024:2021 zones templates
- the moisture sources (without people) were switched off by setting the schedule to 0
- the maximum heating and cooling capacity was assumed to be 10 times the capacity of SIA 2024:2021
- SIA 380/2:2022 calculation
- in the calculation the setpoint in the basic design heating type was corrected
- the area calculation of floors against ambient air is fixed
- IFC models and imported objects are switched off in the report
- In the calculation standard SIA 382/2:2011, the SIA 380/2:2022 setpoints with basic design heating type and without
control deviation are used instead of the zone setpoints.
- SIA 380/1
- floor against ambient air: fixed face type selection
- Fixed heat loss calculation if surface is heated and aginst crawl face
- Report: filter external shading and ifc model in report pictures
- Report: Show construction instead of wall type in report picture
- Added Feature: Ventilated construction (surface tab)
> heat transfer coefficient changes
- SIA 180
- Fixed variable legend
- Show model button:
- Warning if no location is selected
- Model input checking algorithm
- Fixed location checking: Compares IDA ICE location with SIA location