0 Votes

Switzerland 4.8.0.2 changelog

Last modified by WikiBot on 2026/07/24 10:24

Switzerland 4.8.0.2 changelog

New in localization Switzerland 4.802 (relative to 4.801)

  • In the weather data database, the reference height for wind measurements was adjusted according to SIA 2028:2010
  • SIA 2024:2021 zones templates
  • the moisture sources (without people) were switched off by setting the schedule to 0
  • the maximum heating and cooling capacity was assumed to be 10 times the capacity of SIA 2024:2021
  • SIA 380/2:2022 calculation
  • in the calculation the setpoint in the basic design heating type was corrected
  • the area calculation of floors against ambient air is fixed
  • IFC models and imported objects are switched off in the report
  • In the calculation standard SIA 382/2:2011, the SIA 380/2:2022 setpoints with basic design heating type and without
    control deviation are used instead of the zone setpoints.
  • SIA 380/1
  • floor against ambient air: fixed face type selection
  • Fixed heat loss calculation if surface is heated and aginst crawl face
  • Report: filter external shading and ifc model in report pictures
  • Report: Show construction instead of wall type in report picture
  • Added Feature: Ventilated construction (surface tab) > heat transfer coefficient changes
  • SIA 180
  • Fixed variable legend
  • Show model button:
  • Warning if no location is selected
  • Model input checking algorithm
  • Fixed location checking: Compares IDA ICE location with SIA location