IDA Tunnel 1.2.1
Changelog IDA Tunnel 1.2.1 (rel. to IDA Tunnel 1.2)
===================================================
+ Support scrolling lists with mouse wheel and zooming graphical views with Ctrl+wheel
+ The number of subsegments in a section is limited to at least three
+ Possible to copy and paste text from summary page of version projects to Excel
+ Added warning if a temperature sensor is located in a place where the measured signal may be wrong
+ Allow saving a system again before it is completely packed
+ Disabled autosave when running in batch mode
+ Length of segment in vehicle traffic model is set to max(40, min(200, dxMax))
+ In fan report, added item for filters and given flow models
+ In the Route form, the end speed in the last segment of a route is not changed when clicking the Rebuild route button
+ Enhanced appearance of graphical elements of type "Name+Value+Unit"
Changes in models
-----------------
+ Entry Pressure losses for outflow of tunnel now computed using air
density in tunnel, not ambient air density as before.
+ Route Fixed stochastic delay.
+ Way Support shorter traffic segments
Smoother speed measure signal in case of zero traffic flow
+ Section Restore bug fix in sensors (omitted in version 1.2)
+ Section Changes in sensors: air and wall temperatures are computed
by interpolation between midpoints of segments
(instead of interpolation between nodes). Temperature sensor
outside midpoint of outermost segment gets segment temperature.
+ Section Fire power is now always limited for low air flows if
"Zero air flow power reduction" is greater than 0.
Fixed bugs
----------
+ Fixed binding of exit fraction (in road traffic branches) to tables.
Did not work when the alternative "1:" was selected in the connection dialog
+ Fixed connection of transversal duct to climate processor model.
+ Avoid crash in case of missing design day date
+ Fixes version number in input data report
+ Fixed generation of mean temperatures from climate files with extra columns
+ Fixed parameter Fire Reduction (changing the value of "Zero air flow power
reduction" in "Edit segments" dialogue had no effect)
+ Fixed pressure sensor
+ Fixed time events for stochastic delay (big stochastic delays between trains could
make the impact of some trains missed in the simulations)
+ Fixes the problem with activation and deactivation of program in case or errors
in the communication with license server
+ Fixed export variables from path report to Excel
+ Fixed loosing dialog boxes when moving them on a dual monitor in case then the
dual monitor is placed on the left or on the top of the main monitor.
+ Fixed sign of flow variables in 3D path diagram for section where the direction
of the path is from right to left
+ Fixed temperature field in tunnel walls when wall definition consists of several layers
+ Fixed checking position and cross-section area of fan duct components
+ Fixed mapping of parameter tauSES in SES branches to the globally defined value